February 22, 2011 – Radiologists who interpret a high volume of mammograms may not detect more cancers but are better at determining which suspicious lesions are not malignant, according to a new study published in Radiology.

“Contrary to our expectations, we observed no clear association between volume and sensitivity,” said the study’s lead author, Diana S.M. Buist, Ph.D., MPH, senior investigator at the Group Health Research Institute in Seattle. “We did, however, find that radiologists with higher interpretive volume had significantly lower false-positive rates and recalled fewer women per cancer detected.”

An exam result is considered to be a false positive when further testing is recommended for a suspicious lesion but no cancer is found. In addition to causing anxiety for patients, false positives prompt additional testing that costs approximately $1.6 billion per year, Buist said.

The study, partially funded by the American Cancer Society and the National Cancer Institute, included a review of data from six Breast Cancer Surveillance Consortium mammography registries in California, North Carolina, New Hampshire, Vermont, Washington and New Mexico.

The researchers examined various measures of interpretive volume in relation to screening performance for 120 radiologists who interpreted 783,965 screening mammograms between 2002 and 2006. Volume was measured in four ways: the number of screening and diagnostic mammograms read by a radiologist annually – both separately and in combination – and the ratio of screening to total (diagnostic plus screening) mammograms. Screening performance was measured by sensitivity (the ability to detect all cancers present) and false-positive and cancer detection rates.

The results showed that performance varied not only by the number of exams interpreted, but also by the ratio of screening to total (diagnostic plus screening) mammograms.

“Our analysis demonstrated that screening interpretive performance is unlikely to be affected by volume alone, but rather by a balance in the interpreted exam composition,” Buist said. “The data suggest that radiologists who interpret screening mammograms should spend at least a portion of their time interpreting diagnostic mammograms, because radiologists who interpreted very few diagnostic mammograms had worse performance, even if they read a high volume of screening mammograms.”

The study found that radiologists with higher annual interpretive volumes had lower false-positive rates, while maintaining sensitivity rates similar to their lower-volume colleagues. As a result, the researchers simulated the effect of increasing the minimum interpretive volume required of radiologists practicing in the United States, which is currently 960 mammograms every two years.

Based on 34 million women aged 40-79 receiving screening mammograms each year, the researchers estimated that increasing the annual minimum total volume requirement to 1,000 would result in 43,629 fewer women being recalled. The estimated cost associated with false-positive results would be reduced to $21.8 million.

“Recommending any increase in U.S. volume requirements would entail crucial decisions about the relative importance of cancer detection versus false positive exams and workforce issues, since changes could curtail workforce supply and women’s mammography access,” Buist said.

For more information: www.radiology.rsna.org


Related Content

News | FDA

Feb. 2, 2026 — Imagion Biosystems, Ltd. has submitted an Investigational New Drug (IND) application with the U.S. Food ...

Time February 02, 2026
arrow
News | Breast Imaging | Washington University

Jan. 22, 2026 — In breast cancer, a biopsy is the only diagnostic procedure that can determine if a suspicious lump or ...

Time January 29, 2026
arrow
News | Radiation Oncology

Jan. 27, 2026 — Researchers at the Icahn School of Medicine at Mount Sinai, in collaboration with other leading ...

Time January 29, 2026
arrow
News | Magnetic Resonance Imaging (MRI)

Jan. 27, 2026 — Hyperfine has announced results from the largest data set to date evaluating stroke detection with its ...

Time January 28, 2026
arrow
News | Radiology Education

Jan. 22, 2026—The American Roentgen Ray Society (ARRS) will host a live virtual symposium, "Medical Imaging for ...

Time January 28, 2026
arrow
News | PET Imaging

Jan. 26, 2026 — Nuclidium, a clinical-stage radiopharmaceutical company developing a proprietary copper-based ...

Time January 27, 2026
arrow
News | Computed Tomography (CT)

Jan. 21, 2026 — Aidoc recently announced that the U.S. Food and Drug Administration (FDA) cleared the industry's first ...

Time January 23, 2026
arrow
News | Point-of-Care Ultrasound (POCUS)

Jan. 22, 2026 — Qure.ai has received a grant from the Gates Foundation to develop a large open-source multi-modal ...

Time January 23, 2026
arrow
News | PACS

Jan. 21, 2026 — Fujifilm Healthcare Americas Corp. and Voicebrook, Inc. have announced a strategic partnership to ...

Time January 22, 2026
arrow
News | Radiology Education

Jan. 20, 2026 — The American Society of Radiologic Technicians (ASRT) Foundation has named ASRT member Danielle McDonagh ...

Time January 20, 2026
arrow
Subscribe Now