Scientists have found a new use for copper in magnetic resonance imaging (MRI) contrast agent design, that could help to create better images which help doctors diagnose patients’ conditions more easily and safely.

July 27, 2023 — Scientists have found a new use for copper in magnetic resonance imaging (MRI) contrast agent design, that could help to create better images which help doctors diagnose patients’ conditions more easily and safely. 

Researchers discovered a novel copper protein binding site, which does not occur in nature, that has real potential for use in MRI contrast agents used to improve the visibility of internal body structures in scans. 

The discovery overturns conventional medical wisdom that copper is unsuitable for use in MRI contrast agents and could help to develop new imaging agents with potentially fewer risks and side effects than exist with current commonly used contrast agents. 

Researchers from the Universities of Birmingham and St Andrews, as well as Diamond Light Source, published their findings in PNAS after creating a highly elusive abiological copper site bound to oxygen donor atoms within a protein scaffold. 

The experts found that the new structure displayed highly effective levels of relaxivity - the ability of a contrast agent to influence the relaxation times of protons, which helps create clearer and more informative images during an MRI scan

Co-author Dr Anna Peacock, Reader in Bioinorganic Chemistry at the University of Birmingham, commented: “We prepared a new-to-biology copper–binding site which shows real potential for use in contrast agents and challenges existing dogma that copper is unsuitable for use in MRI. 

“Despite copper largely being disregarded for use in MRI contrast agents, our binding site was shown to display extremely promising contrast agent capabilities, with relaxivities equal and superior to the Gd(III) agents used routinely in clinical MRI. Our discovery showcases a powerful approach for accessing new tools or agents for imaging applications.” 

The researchers note that imaging agents based on copper could also be used in Positron emission tomography (PET) scans, which produce detailed 3-dimensional images of the inside of the body.  

Their study shows use of an artificial coiled coil to create the copper site within a protein scaffold has achieved function and performance not normally associated with copper. 

“Metal sites that are not part of the repertoire of biology are vital in providing protein designers with an expanded toolbox of chemistries they can use to design new functional systems such as the promising imaging capabilities reported here,” added Dr Peacock. 

“This opens up applications beyond what biology is currently capable of and showcases some of the advantages of using simple miniature protein scaffolds as a means with which we can engineer new, and maybe currently unknown, metal-binding sites.” 

In MRI scanners, sections of the body are exposed to a strong magnetic field causing hydrogen nuclei of water in tissues to be polarized in the direction of the magnetic field. The magnitude of the spin polarization detected is used to form the MR image but decays with a characteristic time constant known as the T1 relaxation time. 

Water protons in different tissues have different T1 values, which is one of the main sources of contrast in MR images. A contrast agent usually shortens, but in some instances increases, the value of T1 of nearby water protons - altering contrast in the image and improving the visibility of internal body structures, with the most used compounds being gadolinium-based contrast agents (GBCAs). 

Gadolinium (in the form of Gd3+) is often used as a contrast agent, but there are environmental and patient safety concerns making exploration of new contrast agents an important and active research area. Although more work needs to be done to secure the stability of this new copper protein site, the study authors believe their work is a promising first step towards designing new copper-based contrast agents for clinical MRI scanning. 

For more information: https://www.birmingham.ac.uk/


Related Content

News | Radiology Imaging | UC San Diego Health

Oct. 16, 2025 — A strategic collaboration between UC San Diego Health and GE HealthCare will focus on bringing advanced ...

Time October 20, 2025
arrow
Sponsored Content | Videos | Radiology Business

Bayer Radiology’s Barbara Ruhland and Thom Kinst discuss how radiology departments can address the many different ...

Time October 09, 2025
arrow
News | Computed Tomography (CT)

Sept. 26, 2025 — At the American Society for Radiation Oncology (ASTRO) 2025 annual meeting in San Francisco, Calif ...

Time September 29, 2025
arrow
News | Radiopharmaceuticals and Tracers

Sept. 20, 2025 — A promising new PET tracer can visualize a protein that is commonly overexpressed in triple-negative ...

Time September 18, 2025
arrow
News | Radiopharmaceuticals and Tracers

Sept. 11, 2025 — A new PET tracer can provide insights into how spinal cord injuries affect not only the spinal cord ...

Time September 12, 2025
arrow
News | Computed Tomography (CT)

Aug. 26, 2025— Esaote North America, Inc., a provider of dedicated MRI, Ultrasound, and Healthcare IT solutions, has ...

Time August 27, 2025
arrow
News | RSNA

Aug. 13, 2025 — Registration is now open for the RSNA 111th Scientific Assembly and Annual Meeting, the world’s leading ...

Time August 13, 2025
arrow
News | Radiology Imaging

Aug. 12, 2025 – Medical imaging methods such as ultrasound and MRI are often affected by background noise, which can ...

Time August 12, 2025
arrow
News | Artificial Intelligence

July 22, 2025 — GE HealthCare has topped a U.S. Food and Drug Administration (FDA) list of AI-enabled medical device ...

Time July 23, 2025
arrow
News | Prostate Cancer

July 16, 2025 — Artificial intelligence can improve diagnostic consistency and reduce false-positives in prostate cancer ...

Time July 22, 2025
arrow
Subscribe Now