Figure 1: Arterial phase 3-D VIBE FS, PAT 2, 25 second breath-hold, 3 mm, 180 x 320 matrix, 25 x 34 cm


Frank Miller, M.D., medical director of magnetic resonance (MR) at Northwestern Memorial Hospital Outpatient Imaging Center in Chicago, Ill., shares a case in which he imaged complex liver masses on Siemens’ 1.5 Tesla Magnetom Aera and 30-channel body coil combination.

Case History

A 51-year-old female with a history of malignancy of unknown primary and elevated liver function tests.

Techniques: Axial/coronal sub-second T2 HASTE, axial in/out of phase breath-hold T1 FLASH, axial T2FS, axial diffusion, axial/coronal pre/post contrast breath-hold 2-D T1 FLASH; axial/coronal thick slab 1.5 second HASTE for thick slab MRCP and coronal free-breathing 3-D T2 SPACE for 3-D MRCP.

Case Summary

Evaluation of the liver demonstrates several ill-defined infiltrative masses which demonstrate progressive peripheral enhancement on delayed phase sequences with lack of central enhancement (see Figure 1).

There is marked intra-hepatic ductal dilatation associated with these lesions which has progressed from the prior study. The dilation is best visualized by the 3-D SPACE sequence (see Figure 2, below) acquired in a free-breathing acquisition without belts or bellows. An automated phase navigator sequence synchronizes data acquisition to the patient’s breathing for high quality. 

The gallbladder is surgically absent with susceptibility artifact noted in the gallbladder fossa.

Massive conglomerate lymphadenopathy is noted involving the porta hepatis, mesenteric and retroperitoneal regions (see Figure 3, below).

Impression:           

1. Interval progression of ill-defined infiltrative hepatic masses from metastatic disease.

2. Intrahepatic biliary ductal dilatation.

3. Massive conglomerate lymphadenopathy within the upper abdomen appears grossly stable. 

About Siemens 70 cm open bore systems

As the innovator of 70 cm open bore design, Siemens Healthcare delivers MRI systems that allow you to take maximum advantage of the 70 cm bore. The standard, fully digital RF system offers 48 RF channels and 204 coil elements to create an imaging matrix that allows maximum use of coil elements at full FoV without ever running out of RF channels.

Siemens' unique Tim coils allow more flexible scanning positions. Not all patients, such as those with compromised breathing, kyphosis or Paget’s disease, can lie flat on their backs during an MRI exam. With Tim coils, you have the freedom and flexibility to use unique scanning positions (e.g., on a patient’s side) and still obtain the image quality you need for high clinical confidence. In addition, Tim allows full use of parameters (iPAT, Fat Sat, diffusion, etc.) in these positions for high-quality images that provide referring physicians with the information they need to manage their cases.   

Aera: Take your guided tour today
Skyra: Take your guided tour today

For more information: www.medical.siemens.com


Related Content

News | Endoscopes

Oct. 22, 2025 — Fujifilm Healthcare Americas Corp. has launched its advanced endoscopy platform, the ELUXEO 8000 ...

Time October 23, 2025
arrow
News | X-Ray

Oct. 22, 2025 — Imaging technology company Adaptix has begun live imaging trials as part of a research program at the ...

Time October 22, 2025
arrow
News | Contrast Media

Oct. 21, 2025 — Subtle Medical, Inc., a provider of AI-powered medical imaging solutions, has announced positive ...

Time October 21, 2025
arrow
News | Radiology Imaging | UC San Diego Health

Oct. 16, 2025 — A strategic collaboration between UC San Diego Health and GE HealthCare will focus on bringing advanced ...

Time October 20, 2025
arrow
News | Artificial Intelligence

Oct. 20, 2025 — Viz.ai has launched of Viz Assist, a suite of autonomous AI agents that significantly enhance how care ...

Time October 20, 2025
arrow
News | Point-of-Care Ultrasound (POCUS)

Oct. 15, 2025 — GE HealthCare has announced the latest advancement in its Venue family of point-of-care ultrasound ...

Time October 16, 2025
arrow
News | Magnetic Resonance Imaging (MRI)

September 24, 2025—According to the American Journal of Roentgenology (AJR), MRI can reliably identify lateral meniscal ...

Time October 03, 2025
arrow
News | Radiopharmaceuticals and Tracers

Oct. 01, 2025 – Nuclidium AG, a clinical-stage radiopharmaceutical company developing a proprietary copper-based ...

Time October 02, 2025
arrow
News | Radiology Business | Harvey L. Neiman Health Policy Institute

Sept. 30, 2025 — A new study from the Harvey L. Neiman Health Policy Institute found that attrition (i.e., exit) from ...

Time October 02, 2025
arrow
News | Prostate Cancer

Sept. 30, 2025 – EDAP TMS's non-invasive, nonsurgical treatment option, Focal One Robotic HIFU, was featured on national ...

Time September 30, 2025
arrow
Subscribe Now