News | Artificial Intelligence | September 18, 2023

AI system by Lunit identified improperly positioned endotracheal tube on chest radiographs obtained after insertion, as well as on chest radiographs obtained from patients in the ICU at two institutions

AI system by Lunit identified improperly positioned endotracheal tube on chest radiographs obtained after insertion, as well as on chest radiographs obtained from patients in the ICU at two institutions

Left: Chest radiograph from 80-year-old patient in sample A. AI identified endotracheal tube (ETT) with probability score of 0.98, and properly localized tip of ETT (solid arrow). AI also identified tracheal carina with probability score of 0.99 and properly localized carina (open arrow). Based on pixel spacing information in DICOM data header, AI automatically measured absolute distance between ETT tip and tracheal carina (tip-to-carina distance, TCD) as 4.3 cm. AI also measured distance between ETT tip and carina along radiograph’s vertical axis of (y-axis tip-to-carina difference, TCDy) as 4.0 cm, indicating that ETT tip is located 4.0 cm above carina. ETT is in proper position based on TCD. Right: Chest radiograph from 77-year-old patient in sample A. ETT is in critical position, with tip located below tracheal carina. AI-derived TCD was 2.5 cm. AI-derived TCDy was -1.4 cm, indicating that ETT tip is located 1.4 cm below carina. Image courtesy of AJR 


September 18, 2023 — According to an accepted manuscript published in the American Journal of Roentgenology (AJR), an artificial intelligence (AI) system developed by Lunit (Seoul, Korea) identified improperly positioned endotracheal tube (ETTs) on chest radiographs obtained after ETT insertion, as well as on chest radiographs obtained from patients in the ICU at two institutions. 

“Automated AI identification of improper ETT position on chest radiograph may allow earlier repositioning and thereby reduce complications,” wrote corresponding author Eui Jin Hwang, MD, PhD, from the department of radiology at Korea’s Seoul National University Hospital

Hwang et al.’s retrospective AJR study included 539 chest radiographs obtained immediately after ETT insertion from January 1, 2020 to March 31, 2020 in 505 patients (293 men, 212 women; mean age, 63 years) from institution A (sample A); 637 chest radiographs obtained from January 1, 2020 to January 3, 2020 in 304 patients (158 men, 147 women; mean age, 63 years) in the ICU (with or without an ETT) from institution A (sample B); and 546 chest radiographs obtained from January 1, 2020 to January 20, 2020 in 83 patients (54 men, 29 women; mean age, 70 years) in the ICU (with or without an ETT) from institution B (sample C). Lunit’s commercial DL-based AI system was used to identify ETT presence and measure ETT tip-to-carina distance (TCD). Reference standard for proper ETT position was TCD between 3 cm and 7 cm, determined by human readers. Critical ETT position was separately defined as ETT tip below the carina or TCD less than or equal to 1 cm. 

Ultimately, in three patient samples from two different institutions, an AI system identified ETT presence with sensitivity of 99.2–100%; and specificity of 94.5–98.7%, improper ETT position with sensitivity of 72.5–83.7% and specificity of 92.0–100%, and critical ETT position with sensitivity of 100% in all samples and specificity of 96.7–100%. 

For more information: www.arrs.org


Related Content

Feature | Breast Imaging

Despite decades of progress in breast imaging, one challenge continues to test even the most skilled radiologists ...

Time October 24, 2025
arrow
News | Endoscopes

Oct. 22, 2025 — Fujifilm Healthcare Americas Corp. has launched its advanced endoscopy platform, the ELUXEO 8000 ...

Time October 23, 2025
arrow
News | X-Ray

Oct. 22, 2025 — Imaging technology company Adaptix has begun live imaging trials as part of a research program at the ...

Time October 22, 2025
arrow
News | Contrast Media

Oct. 21, 2025 — Subtle Medical, Inc., a provider of AI-powered medical imaging solutions, has announced positive ...

Time October 21, 2025
arrow
News | Artificial Intelligence

Oct. 20, 2025 — Viz.ai has launched of Viz Assist, a suite of autonomous AI agents that significantly enhance how care ...

Time October 20, 2025
arrow
News | CT Angiography (CTA)

Oct. 9, 2025 — RapidAI recently announced that its Lumina 3D built on the Rapid Enterprise Platform has been named to ...

Time October 16, 2025
arrow
News | Point-of-Care Ultrasound (POCUS)

Oct. 15, 2025 — GE HealthCare has announced the latest advancement in its Venue family of point-of-care ultrasound ...

Time October 16, 2025
arrow
News | RSNA 2025

Oct. 7, 2025 — RSNA Ventures, a mission-aligned subsidiary of Radiological Society of North America (RSNA), has ...

Time October 08, 2025
arrow
News | RSNA 2025

Oct. 7, 2025 – Clairity Inc., a leader in AI-based breast cancer risk prediction, will make five scientific ...

Time October 07, 2025
arrow
News | Magnetic Resonance Imaging (MRI)

Oct. 6, 2025 — Hyperfine, Inc. has launched the Portable Ultra-Low-Field Scientific Exchange (PULSE), a subscription ...

Time October 06, 2025
arrow
Subscribe Now