33-year-old, low risk of acute coronary syndrome, presents to off-hour ED with acute chest pain

33-year-old, low risk of acute coronary syndrome, presents to off-hour ED with acute chest pain. Patient underwent coronary CTA using 64-detector row SSCT scanner, with heart rate control. Mean heart rate during acquisition was 89 bpm. Curved MPR images of right coronal artery (A), left anterior descending coronary artery (B), and left circumflex coronary artery (C) show poor image quality. Severe motion artifact is present in distal segments of RCA and LCX, and additional artifact from chest wall movement is present in proximal portion of left main coronary artery, leading to nondiagnostic examination. CT completion time was 236 minutes, disposition time was 79 minutes, and ED LOS was 601 minutes. Patient was discharged from ED without cardiology consultation, and did not undergo invasive coronary angiography or revascularization, nor experienced 30-day all-cause mortality or major adverse cardiovascular event


March 1, 2023 — According to an accepted manuscript published in ARRS’ American Journal of Roentgenology (AJR), using a dual-source CT (DSCT) scanner for coronary CTA can facilitate clinical processes by eliminating the need to administer beta-blockers for heart rate control while decreasing nondiagnostic examinations.

“The findings indicate the potential role of a DSCT scanner with high temporal resolution to help expedite clinical processes in the emergency department (ED) setting,” concluded corresponding author Young Joo Suh, MD, PhD, from Korea’s Research Institute of Radiological Science at the Center for Clinical Imaging Data in Seoul. 

This AJR accepted manuscript included 509 patients (mean age, 52.1 years; 283 men, 226 women) at low-to-intermediate risk for acute coronary syndrome who underwent coronary CTA for acute chest pain in a single ED during the off hours of March 1, 2020 to April 25, 2022. A total 205 patients initially underwent CTA using a 64-detector single-source CT (SSCT) with heart rate control—oral beta-blocker administration if heart rate was faster than 65 beats per minute. Following scanner replacement on April 26, 2021, 304 patients underwent CTA using a third-generation DSCT without heart rate control. Cohorts were compared via length of stay (LOS) in the ED, as well as CT completion time (i.e., from ordering CTA to complete acquisition). Additional endpoints for Suh et al. included image quality and nondiagnostic examinations based on radiology reports.

Ultimately, DSCT without heart rate control—compared to SSCT with heart rate control—showed no difference in ED LOS (505 vs. 457 minutes; p=.37), but shorter CT completion time (95 vs. 117 minutes; p<.001), lower frequency of nondiagnostic examinations (1.6% vs. 6.3%, p=.01), and no difference in cardiology consultation, angiography, disposition, or revascularization (p>.05).

Noting an array of factors, especially patient disposition and onboarding processes, can affect overall length of stay, “the reduction in CT completion time through use of the DSCT system can still provide overall benefit in the ED setting,” the authors of this AJR accepted manuscript added.

For more information: www.arrs.org


Related Content

News | Endoscopes

Oct. 22, 2025 — Fujifilm Healthcare Americas Corp. has launched its advanced endoscopy platform, the ELUXEO 8000 ...

Time October 23, 2025
arrow
News | X-Ray

Oct. 22, 2025 — Imaging technology company Adaptix has begun live imaging trials as part of a research program at the ...

Time October 22, 2025
arrow
News | Contrast Media

Oct. 21, 2025 — Subtle Medical, Inc., a provider of AI-powered medical imaging solutions, has announced positive ...

Time October 21, 2025
arrow
News | Radiology Imaging | UC San Diego Health

Oct. 16, 2025 — A strategic collaboration between UC San Diego Health and GE HealthCare will focus on bringing advanced ...

Time October 20, 2025
arrow
News | Artificial Intelligence

Oct. 20, 2025 — Viz.ai has launched of Viz Assist, a suite of autonomous AI agents that significantly enhance how care ...

Time October 20, 2025
arrow
News | Point-of-Care Ultrasound (POCUS)

Oct. 15, 2025 — GE HealthCare has announced the latest advancement in its Venue family of point-of-care ultrasound ...

Time October 16, 2025
arrow
News | Magnetic Resonance Imaging (MRI)

September 24, 2025—According to the American Journal of Roentgenology (AJR), MRI can reliably identify lateral meniscal ...

Time October 03, 2025
arrow
News | Radiopharmaceuticals and Tracers

Oct. 01, 2025 – Nuclidium AG, a clinical-stage radiopharmaceutical company developing a proprietary copper-based ...

Time October 02, 2025
arrow
News | Radiology Business | Harvey L. Neiman Health Policy Institute

Sept. 30, 2025 — A new study from the Harvey L. Neiman Health Policy Institute found that attrition (i.e., exit) from ...

Time October 02, 2025
arrow
News | Computed Tomography (CT)

Sept. 29, 2025 — Many studies have shown the inverse relationship between bone mineral density (BMD) — the gold standard ...

Time September 30, 2025
arrow
Subscribe Now