62-year-old man with history of oropharyngeal cancer, treated by chemoradiation therapy. Contrast-enhanced multiphase DECT of chest performed for surgical planning. Axial image from iodine concentration map, reconstructed from equilibrium-phase acquisition, shows thin ringlike peripheral high iodine concentration, involving nodule’s entire circumference. Nodule underwent resection, revealing oropharyngeal carcinoma metastasis. Case represents true-positive example of using ringlike peripheral high iodine co

62-year-old man with history of oropharyngeal cancer, treated by chemoradiation therapy. Contrast-enhanced multiphase DECT of chest performed for surgical planning. Axial image from iodine concentration map, reconstructed from equilibrium-phase acquisition, shows thin ringlike peripheral high iodine concentration, involving nodule’s entire circumference. Nodule underwent resection, revealing oropharyngeal carcinoma metastasis. Case represents true-positive example of using ringlike peripheral high iodine concentration for diagnosis of pulmonary metastasis.


January 11, 2023 — According to an accepted manuscript published in ARRS’ American Journal of Roentgenology (AJR), ringlike peripheral high iodine concentration maps from dual-energy CT (DECT) can help guide management in patients with known lung cancer and an indeterminate solitary nodule.

“Ringlike peripheral high iodine concentration had excellent interobserver agreement, showed high specificity (albeit poor sensitivity) for differentiating pulmonary metastasis from primary lung cancer, and independently predicted pulmonary metastasis,” wrote AJR first author Yoshinao Sato, MD, PhD, from the Diagnostic Imaging Center at Japan’s Cancer Institute Hospital in Tokyo.

This AJR accepted manuscript study included 93 patients (64 men, 29 women; median age, 70 years) who underwent resection of a primary lung cancer (n=68) or pulmonary metastasis (n=25) corresponding with a solid lesion on preoperative contrast-enhanced DECT performed between April 2020 and March 2021. After constructing venous-phase 120-keV single-energy images, equilibrium-phase 66-keV virtual monoenergetic images, as well as iodine concentration maps, two radiologists independently assessed lesions for the following: spiculated margins, air bronchograms, rim enhancement, and thin ringlike peripheral high iodine concentration.

Ultimately, ringlike peripheral high iodine concentration on DECT showed excellent interobserver agreement (κ=0.80), and had sensitivity of 52% and specificity of 81% for differentiating pulmonary metastases from primary lung cancers. Additionally, the finding independently predicted pulmonary metastasis in multivariate analysis [OR=7.81, 95% CI: 2.28–29.60; p=.001] combining patient and lesion characteristics.

“Iodine concentration maps from DECT could help determine the diagnosis for lesions that are equivocal for pulmonary metastasis on conventional images,” the authors of this AJR accepted manuscript reiterated.

For more information: www.arrs.org


Related Content

News | Endoscopes

Oct. 22, 2025 — Fujifilm Healthcare Americas Corp. has launched its advanced endoscopy platform, the ELUXEO 8000 ...

Time October 23, 2025
arrow
News | X-Ray

Oct. 22, 2025 — Imaging technology company Adaptix has begun live imaging trials as part of a research program at the ...

Time October 22, 2025
arrow
News | Contrast Media

Oct. 21, 2025 — Subtle Medical, Inc., a provider of AI-powered medical imaging solutions, has announced positive ...

Time October 21, 2025
arrow
News | Radiology Imaging | UC San Diego Health

Oct. 16, 2025 — A strategic collaboration between UC San Diego Health and GE HealthCare will focus on bringing advanced ...

Time October 20, 2025
arrow
News | Artificial Intelligence

Oct. 20, 2025 — Viz.ai has launched of Viz Assist, a suite of autonomous AI agents that significantly enhance how care ...

Time October 20, 2025
arrow
News | Point-of-Care Ultrasound (POCUS)

Oct. 15, 2025 — GE HealthCare has announced the latest advancement in its Venue family of point-of-care ultrasound ...

Time October 16, 2025
arrow
News | Magnetic Resonance Imaging (MRI)

September 24, 2025—According to the American Journal of Roentgenology (AJR), MRI can reliably identify lateral meniscal ...

Time October 03, 2025
arrow
News | Radiopharmaceuticals and Tracers

Oct. 01, 2025 – Nuclidium AG, a clinical-stage radiopharmaceutical company developing a proprietary copper-based ...

Time October 02, 2025
arrow
News | Radiology Business | Harvey L. Neiman Health Policy Institute

Sept. 30, 2025 — A new study from the Harvey L. Neiman Health Policy Institute found that attrition (i.e., exit) from ...

Time October 02, 2025
arrow
News | Magnetic Resonance Imaging (MRI)

Sept. 10, 2025 —GE HealthCare announced it has entered into an agreement to acquire icometrix, a company focused on ...

Time September 10, 2025
arrow
Subscribe Now