Technology | Information Technology | June 20, 2019

Software provides dosimetry functionality for molecular imaging and molecular radiotherapy

DOSIsoft Receives FDA 510(k) Clearance for Planet Onco Dose Software

June 20, 2019 — DOSIsoft announced it has received 510(k) clearance from the U.S. Food and Drug Administration (FDA) to market Planet Onco Dose software for its oncology and yttrium-90 (Y-90) microsphere SIRT 3-D dosimetry components.

Planet Onco Dose is a comprehensive software platform dedicated to medical diagnosis aid, therapy response assessment aid, contouring for radiotherapy and internal dosimetry computation, using molecular imaging modalities.

Planet Onco Dose is a modular software suite composed of two main elements:

  • Planet Onco: The oncology module with core system features, comprehensive reviewing of multimodal molecular image series (computed tomography, magnetic resonance imaging, positron emission tomography, single photon emission computed tomography), fusion and registration, automatic and semi-automatic contouring of regions of interest, tumor segmentation, quantification, tumoral activity monitoring and therapy response assessment; and

  • Planet Dose: The dosimetry module including 3-D personalized voxel-based internal dosimetry computation dedicated to molecular radiotherapy (MRT)

Planet Onco provides advanced tools to display, co-register (including deformable registration), compute standardized uptake value and import/export results (contours and quantification results) to/from treatment planning systems and picture archiving and communication system (PACS) devices for assessment, treatment planning and response of patients undergoing a course of oncology treatments.

DOSIsoft has transferred its external radiation therapy advanced software technology to nuclear medicine and molecular radiotherapy. CE marked since March 2016, Planet Onco Dose is the first fully integrated imaging and personalized 3-D dosimetry platform for radionuclide-based therapies, according to the company.

Planet Onco Dose is intended to assist the user in the diagnosis, quantification and verification of radiation doses received by tissues as a result of administering permanent Y90 microsphere implants, as well as in therapy response follow-up.

The software provides tools for post-treatment absorbed dose calculation and evaluation on PET and SPECT images. The following functions are available to allow dose calculations for patients after they have received a treatment using permanent Yttrium-90 microspheres:

  • Three-dimensional (3-D) liver-lung shunt assessment;

  • Voxel-based dosimetry based on 90Y-microspheres-PET (or SPECT Bremsstrahlung) series;

  • Dose computation models: Local Deposition Method and Voxel S Value Dose Kernel Convolution approach;

  • Analysis down to any liver sub region: healthy liver, lobes, tumors, toxicity regions;

  • Advanced and interactive dosimetry quantification (profile, dose-volume histograms, statistics, etc.);

  • Ability to scale to known activity; and

  • Compatible with PET images acquired with another radioisotope (correction of branching ratio and decay parameters).

For more information: www.dosisoft.com


Related Content

Feature | Kyle Hardner

Radiotherapy contributes to about 40% of all cancer cures but still lags behind systemic therapy in funding and ...

Time October 21, 2025
arrow
News | Stereotactic Body Radiation Therapy (SBRT) | American Society for Radiation Oncology

Sept. 29, 2025 — A new clinical trial report finds that stereotactic radiation therapy offers long-term survival ...

Time October 15, 2025
arrow
News | Proton Therapy

Sept. 28, 2025 — Leo Cancer Care has launched Grace, the company's upright photon therapy system. Grace is named after ...

Time October 03, 2025
arrow
News | Prostate Cancer

Sept. 30, 2025 – EDAP TMS's non-invasive, nonsurgical treatment option, Focal One Robotic HIFU, was featured on national ...

Time September 30, 2025
arrow
News | Radiation Therapy | American Society for Radiation Oncology (ASTRO)

Sept. 29, 2025 — Radiation therapy may offer a comparable and potentially safer alternative to repeat catheter ablation ...

Time September 30, 2025
arrow
News | Radiation Therapy

Sept. 26, 2025 – Accuray Inc. has introduced the Accuray Stellar* solution. Initially for the U.S. market, the new ...

Time September 29, 2025
arrow
News | Computed Tomography (CT)

Sept. 26, 2025 — At the American Society for Radiation Oncology (ASTRO) 2025 annual meeting in San Francisco, Calif ...

Time September 29, 2025
arrow
News | Lung Imaging

Sept. 26, 2025 ― Researchers from the University of Texas MD Anderson Cancer Center will present new data at the ...

Time September 29, 2025
arrow
News | ASTRO

Sept. 26, 2025 — Artera, the developer of multimodal artificial intelligence (MMAI)-based prognostic and predictive ...

Time September 29, 2025
arrow
News | Radiation Therapy

Sept. 25, 2025 — GE HealthCare has announced updates to Intelligent Radiation Therapy (iRT), a new version of the ...

Time September 25, 2025
arrow
Subscribe Now