News | Computed Tomography (CT) | February 04, 2026

AJR review finds 25 years of CT Dose reduction preserves diagnostic performance.

Report: Advances in CT Continue to Drive Radiation Dose Reduction

Coronal images are shown. PCD examination included additional dose reduction methods including tin filtration and ultrahigh-resolution acquisition. CTDIvol is lower for PCD than for EID scanner (9 vs 26 mGy, respectively); yet, PCD-CT image has less noise. EID CT examination was performed on Siemens Sensation 64 scanner with following parameters: detector configuration, 32x0.6 mm; z-flying focal spot (64x0.6 mm); tube potential, 120 kV; rotation time, 1 second; helical pitch, 0.9; effective mAs, 170; kernel, H70; slice thickness, 0.75 mm; matrix, 512. PCD-CT examination was performed on Siemens NAEOTOM Alpha scanner with following parameters: detector configuration, 120x0.2 mm; tube voltage, 100 kV with added tin filter; rotation time, 1 second; helical pitch, 0.85; kernel, Hr72 with QIR strength setting of 3; slice thickness, 0.6; mm; matrix, 1024. (Photo: American Roentgen Ray Society)


Feb. 4, 2026 — A new review published in the American Journal of Roentgenology (AJR) finds that advances in CT technology over the past 25 years have enabled routine radiation dose reductions by a factor of 2 to 10, while preserving diagnostic performance when applied appropriately.

Cynthia H. McCollough, PhD, and Lifeng Yu, PhD, of Mayo Clinic Minnesota traced major milestones in CT dose reduction since the early 2000s, highlighting the cumulative impact of hardware innovations, scanning technique optimization and advances in image reconstruction algorithms.

According to Drs. McCollough and Yu, the introduction of photon-counting detector (PCD) CT represents a major leap forward in dose efficiency. PCD CT improves signal quality by rejecting electronic noise, optimizing photon-energy weighting, and enabling ultrahigh-resolution acquisitions without proportional dose penalties.

Importantly, this AJR review cautions that dose reduction alone is not a sufficient metric of progress. The authors emphasize that diagnostic performance must be preserved through objective, task-based image quality assessment, particularly as deep learning–based reconstruction and postprocessing tools are increasingly deployed in clinical practice.

Using historical and contemporary CT examples, McCollough and Yu demonstrate that modern scanners can achieve image quality equal to or superior to that of legacy systems at a fraction of the radiation dose, especially when advances are applied in combination and tailored to specific clinical tasks.

The authors conclude that continued progress in CT dose reduction will depend on close collaboration among radiologists, technologists, and medical physicists, as well as careful validation of emerging technologies to ensure patient safety without compromising diagnostic accuracy.

Watch Dr. McCollough discuss her article reviewing key milestones and technologic innovations that have led to this substantial reduction in CT radiation doses—providing examples of the cumulative impact of these advances on image quality for routine examinations in various anatomic sites.

 


Related Content

News | FDA

April 16, 2026 — Royal Philips has received U.S. Food and Drug Administration 510(k) clearance for the Philips Spectral ...

Time April 20, 2026
arrow
News | X-Ray

April 14, 2026 — KA Imaging is seeing continued adoption of its X-ray technology across new regions, with recent ...

Time April 15, 2026
arrow
News | Ultrasound Imaging

April 9, 2026 — GE HealthCare has announced a digital integration between the GE HealthCare bkActiv intraoperative ...

Time April 09, 2026
arrow
News | Radiology Imaging

April 7, 2026 — Onvida Health and Siemens Healthineers have entered a 10-year Value Partnership¹ designed to bring the ...

Time April 09, 2026
arrow
News | Teleradiology

April 1, 2026 — Premier Radiology Services has acquired Global Imaging Solutions (GLOBIS), a leading teleradiology group ...

Time April 03, 2026
arrow
News | Digital Pathology

March 29, 2026 — Leica Microsystems has introduced the Viventis SCAPE light sheet microscope. Viventis SCAPE enables ...

Time April 01, 2026
arrow
News | Radiology Business

March 31, 2026 — Radon Medical Imaging, a medical imaging equipment maintenance and repair services company, has has ...

Time March 31, 2026
arrow
News | Radiology Imaging

March 26, 2026 — GE HealthCare has announced a renewed research collaboration with Stanford Medicine Department of ...

Time March 30, 2026
arrow
News | Cardiac Imaging

March 28, 2026 — When Ashley Perlow felt a sharp pain shoot across her chest and into both wrists, she didn't think it ...

Time March 30, 2026
arrow
News | Digital Pathology

March 11, 2026 — Royal Philips has announced the expansion of its digital pathology portfolio with new cloud-enabled ...

Time March 26, 2026
arrow
Subscribe Now