News | Breast Density | July 31, 2023

For patients with dense breasts undergoing screening in the incidence setting, a commercial AI tool did not provide additional benefit to mammography with supplementary ultrasound 

For patients with dense breasts undergoing screening in the incidence setting, a commercial AI tool did not provide additional benefit to mammography with supplementary ultrasound

“Mammography with supplementary ultrasound showed higher accuracy, higher specificity, and lower recall rate in comparison to mammography with AI, as well as in comparison to mammography with both US and AI,” wrote corresponding author Hee Jung Moon, MD, PhD, from the department of radiology at South Korea’s Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine. Image courtesy of American Journal of Roentgenology (AJR) 


July 31, 2023 — Findings from an accepted manuscript published in the American Journal of Roentgenology (AJR) suggest that for patients with dense breasts undergoing screening in the incidence setting, a commercial AI tool did not provide additional benefit to mammography with supplementary ultrasound (US). 

“Mammography with supplementary ultrasound showed higher accuracy, higher specificity, and lower recall rate in comparison to mammography with AI, as well as in comparison to mammography with both US and AI,” wrote corresponding author Hee Jung Moon, MD, PhD, from the department of radiology at South Korea’s Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine

This AJR accepted manuscript included 1,325 women (mean age, 53 years) with dense breasts who underwent both screening mammography and supplementary breast US within a 1-month interval from January 2017 to December 2017; prior mammogram and US were available to compare in 91.2% and 91.8%, respectively. Fifteen radiologists (5 staff and 10 fellows) interpreted mammography and US examinations, and clinical reports were used for Moon et al.’s analysis. A commercially available AI algorithm (Lunit INSIGHT, v 1.1.0.0, Seoul, Korea) was used to retrospectively evaluate mammographic examinations for cancer presence. Then, screening performances were compared among mammography, AI, US, and test combinations, using generalized estimating equations. At least 24 months of imaging stability was required for a benign diagnosis. 

Ultimately, mammography with AI, mammography with US, and mammography with both ultrasound and AI showed recall rate of 14.9, 11.7, and 21.4 (all p < .05); sensitivity of 83.3%, 100.0%, and 100.0% (all p > .05); specificity of 85.8%, 89.1%, and 79.4% (all p < .05); and accuracy of 85.7%, 89.2%, and 79.5% (all p < .05). 

For more information: www.arrs.org 

 

Related Breast Density Content: 

VIDEO: FDA Update on the US National Density Reporting Standard - A Discussion on the Final Rule 

One on One … with Wendie Berg, MD, PhD, FACR, FSBI 

Task Force Issues New Draft Recommendation Statement on Screening for Breast Cancer 

Creating Patient Equity: A Breast Density Legislative Update 

FDA Needs to Ensure that Information on Dense Breast Notifications are Clear and Understandable to all Members of the Public 

AI Provides Accurate Breast Density Classification 

VIDEO: The Impact of Breast Density Technology and Legislation 

VIDEO: Personalized Breast Screening and Breast Density 

VIDEO: Breast Cancer Awareness - Highlights of the NCoBC 2016 Conference 

Fake News: Having Dense Breast Tissue is No Big Deal 

The Manic World of Social Media and Breast Cancer: Gratitude and Grief 

 

Related Breast Imaging Content: 

Single vs. Multiple Architectural Distortion on Digital Breast Tomosynthesis 

Today's Mammography Advancements  

Digital Breast Tomosynthesis Spot Compression Clarifies Ambiguous Findings  

AI DBT Impact on Mammography Post-breast Therapy  

ImageCare Centers Unveils PINK Better Mammo Service Featuring Profound AI  

Radiologist Fatigue, Experience Affect Breast Imaging Call Backs  

Fewer Breast Cancer Cases Between Screening Rounds with 3-D Mammography 

Study Finds Racial Disparities in Access to New Mammography Technology 

American College of Radiology (ACR) Launches Contrast-Enhanced Mammography Imaging Screening Trial (CMIST) in Collaboration With GE Healthcare and the Breast Cancer Research Foundation


Related Content

Feature | Breast Imaging

Despite decades of progress in breast imaging, one challenge continues to test even the most skilled radiologists ...

Time October 24, 2025
arrow
News | Contrast Media

Oct. 21, 2025 — Subtle Medical, Inc., a provider of AI-powered medical imaging solutions, has announced positive ...

Time October 21, 2025
arrow
News | Artificial Intelligence

Oct. 20, 2025 — Viz.ai has launched of Viz Assist, a suite of autonomous AI agents that significantly enhance how care ...

Time October 20, 2025
arrow
News | CT Angiography (CTA)

Oct. 9, 2025 — RapidAI recently announced that its Lumina 3D built on the Rapid Enterprise Platform has been named to ...

Time October 16, 2025
arrow
News | Point-of-Care Ultrasound (POCUS)

Oct. 15, 2025 — GE HealthCare has announced the latest advancement in its Venue family of point-of-care ultrasound ...

Time October 16, 2025
arrow
News | Breast Imaging

Oct. 15, 2025 — Leading into Breast Cancer Awareness Month, Fujifilm Healthcare Americas Corp. and Beekley Medical ...

Time October 15, 2025
arrow
News | RSNA 2025

Oct. 7, 2025 — RSNA Ventures, a mission-aligned subsidiary of Radiological Society of North America (RSNA), has ...

Time October 08, 2025
arrow
News | RSNA 2025

Oct. 7, 2025 – Clairity Inc., a leader in AI-based breast cancer risk prediction, will make five scientific ...

Time October 07, 2025
arrow
News | Magnetic Resonance Imaging (MRI)

Oct. 6, 2025 — Hyperfine, Inc. has launched the Portable Ultra-Low-Field Scientific Exchange (PULSE), a subscription ...

Time October 06, 2025
arrow
News | Breast Imaging

Oct. 3, 2025 — Gnosis for Her, a mobile breast health initiative redefining comfort and access in women's breast imaging ...

Time October 06, 2025
arrow
Subscribe Now